Skip to main content

Table 11 The expected values and variances of the biofilm model at time t=100 computed by the MEgPC approach, the UKF and the stochastic collocation method

From: An accuracy comparison of polynomial chaos type methods for the propagation of uncertainties

Method

Expected value

Variance

MEgPC

1.349

1.707

UKF

1.388

1.801

SCM order 5

1.352

1.706

SCM order 9

1.352

1.706