Table 2 Comparison of singlerate and multirate approach corresponding CPU-time and average real time factor for the three-phase inverter with cooling system simulation

From: Multirate DAE-simulation and its application in system simulation software for the development of electric vehicles

Case CPU-Time Avg RTF
Singlerate (Fixed: 1 μs) 320.60 641.198024
Multirate (Synctime: 1 ms) 52.44 104.872401
Multirate (Synctime: Multiple) 51.75 103.492756